OPERATOR’S MANUAL
67386
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
RELEASED: 3-28-06
REVISED:
(REV. 03)
8-2-10
CYCLE SENSOR KITS
(CLOSED ELECTRICAL CONTACT TYPE)
FOR 3/8” & 1/2” DIAPHRAGM PUMPS
CYCLE SENSOR KITS
67386 SENSOR INSTALLATION
67386 can be used on the following diaphragm pumps:
3/8” -- PD03P-XXX-XXX
1/2” -- PD05A-XXX-XXX-B, PD05P-XXX-XXX-B and PD05R-XXX-
XXX-B
Refer to figure 4.
1. Remove (134) bolts from the major valve and remove (135) valve
block.
2. Remove (141) valve plate and (140) valve insert from the valve
block.
3. Remove (136) plug and (111) spool. Assemble 67407 spool and
(136) plug into valve block. NOTE: Apply Lubriplate (94276) to all
“O” rings, “U” cups and mating parts.
4. Replace (140) valve insert and (141) valve plate in valve block.
NOTE: Assemble (140) valve insert with “dished” side toward (141)
valve plate.
5. Assemble 96563 adapter (with 95276 sensor attached) to valve
block. Attach (135) valve block to (101) motor body, using (134)
bolts. NOTE: Torque to 15 - 20 in. lbs (1.7 - 2.3 Nm).
GENERAL DESCRIPTION
The ARO diaphragm pump cycle sensor kits provide a closed contact
output each time the pump completes a cycle. This signal may be used
to record cycles for maintenance purposes or batching if the discharge
volume of each complete cycle is known.
Some parts of the pump must be replaced with those includedin thekits
to enable the activation of the switch.
OPERATION
140
132
141 k
Maximum Operating Voltage - 200 V DC.
Switching Current - 0.5 Amps
Once the kit is installed in the pump, it may be interfaced with a control
device in the following ways:
As a SOURCING switch (see figure 1) for use with PLC’s.
As a SINKING switch (see figure 2) for use with PLC’s.
As a closed contact switch (see figure 3) for use with meters.
. 134
135
Sourcing Switch
+V
Identification dot this side.
INPUT
111
136
Figure 1
g
67407
Sinking Switch
INPUT
Y325-29 (2) g
95276 g
Figure 2
96563 g
Closed Contact Switch
Included but not shown:
94276 Lubriplate grease
95275 Magnet
INPUTS
Figure 3
k Assemble with identification dot toward (132) gasket.
.Torque to 15 - 20 in. lbs (1.7 - 2.3 Nm).
g Included in 67386 kit.
Figure 4
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
FAX(800) 892-6276
(800) 495-0276
© 2010
CCN 15257850
|
Insignia Home Theater System NS HT511 User Manual
Insignia Stereo System NS ES6111 User Manual
Intel Food Processor SA 1110 User Manual
Invacare Marine Sanitation System 9669 User Manual
JBM electronic Network Router C20 through C21 User Manual
John Deere Water Pump AC CP2GH User Manual
JVC MP3 Player HR XVS44U User Manual
JVC TV Receiver LT 32E478 User Manual
Kenwood Hot Beverage Maker SJM282 User Manual
Koolatron Convection Oven Z100B User Manual