S I M P L Y
A M A Z I N G ®
USER’S GUIDE
XL5-105HH
XL5-205HH
HIGH SPEED UPRIGHT VACUUM
CLEANER WITH
®
CLEANING SYSTEM
•IMPORTANT•
SAVE THIS BOOKLET!
Includes:
• Safety Warnings
• Warranty
• Operating Instructions
• Trouble Diagnosis
• Accessories
BEFORE OPERATING CLEANER,
READ ALL INSTRUCTIONS IN
THIS MANUAL CAREFULLY.
IMPORTANT SAFETY
INSTRUCTIONS
When using an electrical appliance, basic
precautions should always be followed,
including the following:
Table of Contents
Maintenance and Customer Service, Plug Fitting Instructions,
Accessories, Important Safety Instructions . . . . . . . . . . . . . . . page
READ ALL INSTRUCTIONS BEFORE
USING THIS VACUUM CLEANER
2
Warranty, Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . page
3
Parts List, Assembly, Operating Instructions,
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page
WARNING
4
To reduce the risk of fire,
electric shock, or injury:
To Replace Filter Dust Bag, How to Replace a Worn Belt,
To Adjust or Replace Brush, Using an Oreck Fresh Air® Tab,
Bulb Replacement, Stuffing or Blockage . . . . . . . . . . . . . . . . . page
5
• Do not leave appliance unattended when plugged in.
Unplug from outlet when not in use and before servicing.
• Do not use outdoors or on wet surfaces.
• Do not operate the unit while in the upright and locked
position.
• Do not let the unit run while in any one stationary position
for any period of time. Keep the unit moving while in
operation.
Maintenance and Customer Service
Your Oreck vacuum cleaner is a product of precise engineering. The
motor bearings are permanently lubricated and should not be oiled. If
you require additional information or have problems with your Oreck
vacuum, you may call ORECK customer service at: 0845 603 0153
Or write to:
• Do not allow to be used as a toy. Close attention is
necessary when used by or near children.
Oreck UK
P.O. Box 107
Exeter
DEVON
EX2 8ZQ
• Use only as described in this manual. Use only
manufacturer’s recommended attachments.
• Do not use with damaged cord or plug. If appliance is not
working as it should, has been dropped, damaged, left
outdoors, or dropped into water, return it to a service
center or call customer service at: 0845 603 0153.
• Do not pull or carry by cord, use cord as a handle, close
door on cord, or pull cord around sharp edges or corners.
Keep cord away from heated surfaces.
Please specify the model number and serial/code number which can be
found on the data plate on the back of the vacuum.
Save your sales or purchase slip. Should your Oreck appliance require
warranty service, present this slip to the Authorized Service Center as
your proof of purchase date.
• Do not run appliance over cord.
• Do not unplug by pulling on cord. To unplug, grasp the
plug, not the cord.
Plug Fitting Instructions
• Do not handle plug or appliance with wet hands.
• Do not put any object into openings. Do not use with any
opening blocked; keep free of dust, lint, hair and anything
that may reduce air flow.
The wires in this main lead are coloured in accordance with the
following code:
Blue: Neutral
Brown: Live
• Keep hair, loose clothing, fingers and all parts of body
away from openings and moving parts.
• Do not use to pick up anything that is burning or smoking,
such as cigarettes, matches, or hot ashes.
• Do not use without filter bag assembly in place.
• Turn off all controls before unplugging.
As the colours of the wires in the main lead of this appliance may not
correspond with the coloured markings identifying the terminals in your
plug, proceed as follows;
The wire which is coloured Blue must be
connected to the terminal which is
marked with the letter N or coloured
Black.
• Use extra care when cleaning on stairs.
• Do not use to pick up flammable or combustible liquids,
such as gasoline or lighter fluid, or use in areas where
they may be present.
The wire which is coloured Brown must
be connected to the terminal which is
marked with the letter L or coloured Red.
• Do not use appliance in an enclosed space where
flammable, explosive or toxic vapors are given off by oil
base paint, paint thinner, some mothproofing substances,
or in an area where flammable dust is present.
• Do not pick up toxic material such as chlorine bleach,
drain cleaner, gasoline, etc. with this appliance.
• Use caution when vacuuming over area rug edges and
fringe.
Neither wire is to be connected to the
earth pin of the 3 pin plug.
When changing fuse, replace with the
same size.
Accessories (Sold Separately)
ITEM
PART #
CCPK8DW
CCPK8
0300604
AIRTABS
00965-0019
SAVE THESE INSTRUCTIONS
1. Dust Bag, 8 Pack, Hypo-Allergenic
Dust Bag, 8 Pack, Regular
2. Belts, 3 Pack
3. Oreck Fresh Air® Tabs
4. Light Bulb
Household Use Only
2
Warranty
Troubleshooting Guide
ORECK MANUFACTURING COMPANY: (Oreck 21180 Johnson Road;
Long Beach, MS, USA 39560 gives you the following warranty for this
product only if it was originally purchased for residential use, not resale
from Oreck or an Oreck Authorized Retail Dealer.)
WARNING: Unplug cord from electrical
outlet before servicing.
SAVE SERVICE CALLS...CHECK THESE FIRST:
• Is the disposable filter dust bag full?
• Are pores of filter dust bag clogged with powder or fine dust?
Oreck will repair or replace, free of charge, to the original purchaser, any
part that is found to be defective in material or workmanship within five (5)
years of the date of purchase; ten (10) years on housing. This warranty
applies to normal domestic use. Any commercial use of this product will
void this warranty.
• Is anything clogging the revolving brush, lower tube, intake opening,
fan housing or connector assembly opening?
• Is the belt in place and turning the brush?
• Are the brush ends in the proper location?
This warranty does not cover the replacement of expendable or
consumable parts such as belts, brushes, bulbs, disposable bags and
other parts subject to normal wear unless they are defective in material or
workmanship.
• Does the brush turn freely? Are hair, string or rug fibers wound around
the brush?
This warranty does not apply to any part subjected to accident, abuse,
alteration, misuse, damage caused by act of God, the use of voltages
other than indicated on the serial number displayed on this product or
service of this product by other than Oreck or a participating Factory
Authorized Service Center.
PROBLEM
CLEANER
POSSIBLE SOURCE
AREAS TO CHECK
Not plugged in
properly.
Be sure cleaner is
firmly plugged into
wall outlet.
WILL NOT RUN
Oreck does not authorize any person or representative to assume or
grant any other warranty obligation with the sale of this product.
No electricity in wall
outlet.
Check electrical
source–fuse or
circuit breaker.
Oreck’s warranty is valid only if you retain proof of purchase from Oreck
or an Oreck Authorized Retail Dealer for this product. If you purchase this
product from any other source, your purchase is “AS IS,” which means
Oreck grants you no warranty, and that you, not Oreck, assume the entire
risk of the quality and performance of this product, including the entire
cost of any necessary servicing or repairs of any defects.
CLEANER
DOES NOT PICK UP
Filter bag is full.
Replace filter bag.
See “Replace Paper
Filter Dust Bag.”
This warranty is in addition to your statutory and other legal rights.
Nozzle or intake
pivot clogged.
Clear obstruction.
Replace belt.
Reconditioned units carry a 6 month warranty from date of purchase.
Belt is broken or
stretched.
Brush is worn.
See “To Adjust or
Replace Brush.”
Bag tube clogged.
Clear obstruction.
Change bag.
Bag pores are
clogged with fine
dust.
Impeller fan is
broken.
Return to Service
Center for repair.
Revolving brush is
not even at both
ends.
Check brush roll end
cards. Make sure
words “OLD” or “NEW”
match at each end.
ALL OTHER SERVICING SHOULD BE DONE BY AN
ORECK AUTHORIZED SERVICE CENTER.
CALL CUSTOMER SERVICE HOT LINE
0845 603 0153
Whenever calling, please be sure to have your model and serial
number from data plate.
3
Operating Recommendations
Parts List
This new ORECK XL High-Speed Upright is one of the finest, fastest,
and strongest units in its class. You’ll love the way it cleans, gets under
things, and it’s SO lightweight and easy to use.
To assist you in identifying components of your vacuum, the parts have
been numbered as follows:
The following are a few simple suggestions regarding its
operation:
10
1
2
3
4
5
6
7
8
9
Handle section, upper
Tube, lower
Power head
Outer bag
Paper filter dust bag
Power cord
Retaining spring
Bag tension bar
Zip fastener
11
9
1. When inserting a new disposable paper filter dust bag—FIRST
PUFF OUT and OPEN THE BAG.
1
12
2. When the disposable filter dust bag is full, REPLACE IT.
3. If at any time the machine does not pick up properly or makes an
unusual noise, STOP OPERATION and service.
16
5
4. Although your upright will pick up pins, paper clips, and other
small objects, it is recommended that these be removed from the
floor before you vacuum. Failure to do so may result in permanent
damage to the motor suction fan and its housing.
13
4
10 On/Off switch
11 Cord hook
12 Plastic loop/cable clamp
13 Connector assembly
14 Fan housing
2
5. WARNING: Do not use your vacuum cleaner on damp or wet
surfaces. This will cause damage to the vacuum cleaner and is
dangerous to the user. Damage caused by use on wet or damp
surfaces is not covered under warranty.
6
15 Cord assembly
14
6. REPLACE THE BELT EVERY 6 MONTHS.
7
16 Cord Strain Relief Assembly
8
15
7. Change the disposable filter dust bag at least once a month—
even if it is not full! The collected dust in the dust bag can cause
odor, attract moisture, and can affect the efficiency of the cleaner.
3
8. DO NOT run the vacuum cleaner over the cord. The revolving
brush could damage the cord.
Assembly
9. Use caution when vacuuming over area rug edges and fringe.
fig. 1 Before assembling appliance, remove two screws from
connector assembly. Remove cardboard insert by pulling
upward.
General Information
The performance of your new cleaner greatly depends upon care and
maintenance. The instructions in this manual will guide you in
performing basic care and maintenance. To obtain the most satisfying
years of service read the instructions and keep them handy for future
reference.
fig. 2 With ON/OFF switch facing the front of the unit, slide
upper handle section over matching section of the
connector assembly. Hold tab of cord strain relief flush
with TOP hole in connector assembly. Insert screw
through hole in tab of cord strain relief and firmly tighten
to connector assembly. Insert remaining screw in bottom
hole of connector assembly and tighten firmly.
Disposable Paper Filter Dust Bags
Disposable paper filter dust bags play a very important role in the
efficiency of your ORECK vacuum cleaner. The purpose of the paper
bag is to trap dirt, but at the same time it must be porous enough to
allow air to pass through. If the paper bag becomes clogged, no air can
pass through the cleaner and cleaning cannot take place, regardless of
the cleaner’s power.
NOTE: The power cord comes installed in the cord strain
relief. Should the power cord come loose, simply pinch
the power cord together and slide approximately 1 - 2
inches through hole in cord strain relief. Carefully slide
power cord over clamp on the cord strain relief and pull
excess until the power cord is tightly rested under clamp.
To keep your cleaner operating at maximum efficiency, change the dust
bag frequently. DO NOT FILL ABOVE THE LINE INDICATED ON THE
DUST BAG.
Be sure the disposable paper filter dust bag is installed properly.
fig. 3 Attach cord to cord clip by pressing cord above and
All paper dust bags are not the same. Your ORECK disposable
dust bags have been designed to be used with the ORECK cleaner.
Using bags other than genuine ORECK TYPE CC disposable bags
will affect the cleaning ability of your cleaner and could cause
damage to it.
below clip ensuring the cord is fully rested in clip.
Operating Instructions
The Belt
Make sure disposable paper filter dust bag is in place. DO NOT operate
The belt on your vacuum cleaner controls the speed of the revolving
brush and is very important for the effective operation of the cleaner. If
the belt becomes stretched or cut, it will cause the revolving brush to
stop completely or slow down. See instructions in the manual for
replacing belt.
the cleaner without a paper filter dust bag. Plug the power cord into an
electrical outlet and press the On(l) - OFF(O) switch on handle assembly
when ready to operate.
An extra belt is stored in the baseplate of your cleaner. When
buying replacement belts, use ONLY ORECK genuine belts. Belts
other than Oreck belts will not operate the revolving brush
correctly and may create undue stress which will cause damage to
the motor and brush bearings. Using belts other than ORECK belts
will void the warranty.
Up-Position Lock
fig. 4 Place foot on power head and lean handle back gently to release
lock for vacuum use. Return handle to the full upright position to
engage lock.
NOTE: Do not operate the unit while in the upright and locked position.
Do not let the unit run while in any one stationary position for any period
of time. Keep the unit moving while in operation.
Lubrication
The vacuum cleaner motor bearings are factory lubricated and sealed.
Further lubrication is not required.
For Easy Power Cord Storage
fig. 5 Wrap power cord around cord hook on handle and cord hook on
connector.
4
General Cleaner Care
To Adjust or Replace Brush
At least once a month, check for and
remove excessive lint, string or hair from
revolving brush.
WARNING: Unplug cord from electrical
outlet before servicing.
Wipe the outside of the cleaner with a
damp cloth. Also clean the connector
deflector assembly area, base of cleaner
and fan housing area. If there is dust in the
outer bag, vacuum it or shake it out.
fig. 16 To determine if the brush is worn, place a firm straight edge
across the nozzle opening. If brush bristles do not extend
beyond baseplate, brush should be adjusted.
fig. 17 Remove the baseplate by removing 5 screws.
fig. 18 Remove the belt and brush roll from the housing.
A little preventative maintenance will keep
your cleaner looking new and will ensure
continued cleaning effectiveness.
fig. 19 Rotate both bearing assemblies at ends of brush roll to show
"OLD" and replace in the holding channels in the housing.
NOTE: The bearing assembly setting marked "OLD" has no ribs on the
top of the assembly. The one marked "NEW" has several ribs. When
rotating bearings, make sure both bearing assembly settings are the
same and face up when replacing the brush roll.
CAUTION—Wood Floors, Soft (Vinyl, Asphalt Tile, etc.) Floor
Surfaces and Polished Floor Finishes
Use floor and floor finish manufacturer’s recommended methods of
cleaning. The metal strip on the base of the cleaner could be damaged
if used on concrete or abrasive surfaces, and, therefore, cause damage
to wood floors, soft (vinyl, asphalt tile, etc.) floor surfaces and polished
floor finishes. The roller brush may also scuff very soft finishes. Do not
operate the unit while in the upright and locked position. Do not let the
unit run while in any one stationary position for any period of time. Keep
the unit moving while in operation.
fig. 16 Reassemble the belt and the baseplate and check bristle height
above baseplate at each end of brush.
If a previous adjustment has already been made and bristle height does
not extend above baseplate, a new brush assembly should be ordered.
IMPORTANT: Unless the brush is worn as indicated above, both
bearings must be in the “NEW” position. When rotating, both
bearings must be in the “OLD” position. Unmatched settings will
cause damage to your machine.
XL5: Celoc® Hypo-Allergenic Filter System
The Celoc SMMS outer bag of your vacuum cleaner is high filtration
medical material designed to filter the smallest of dust particles. It is
important the inside of the outer bag be cleaned. Vacuum the inside of
the outer bag or hand wash, turned inside out, with warm water, and air
dry. For best results, the Celoc SMMS outer bag should be replaced
once a year. The Celoc layered disposable inner dust bag must be
replaced once a month even if it is not full. Change it more often if it is
used in extremely dirty areas. Increase the cleaning power of your
vacuum by changing the bag often.
Using An Oreck Fresh Air® Tab
fig. 20 Your ORECK XL vacuum cleaner has a special ORECK FRESH
AIR® tab pocket. This light-colored pocket is located inside the
vinyl bag in the area where the paper disposable bag attaches
to the intake tube. Insert tablet in pocket if desired.
Bulb Replacement
To Replace Filter Dust Bag
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 21 Remove lamp housing by removing two (2) screws in the the
top of the lamp housing. Pull burned out bulb from holder and
replace with new bulb. Use only Oreck replacement parts.
Reassemble lamp housing by replacing two screws in the top of
the lamp housing.
WARNING: Unplug cord from electrical
outlet before servicing.
BAG REMOVAL:
fig. 6 Unzip outer bag completely.
fig. 7 Pull bag cardboard collar to release bag dock door from
connector. Bag dock door will hinge downward.
Stuffing or Blockage
fig. 8 Gently pull bag cardboard collar upward out of the bag dock.
The dust seal will close automatically.
IMPORTANT: On plush and new carpets, stuffing may occur inside the
the intake tube and the lower tube assembly. This is due to excessive fuzz
and loose cuttings in the carpet. Stuffing could occur for the first few
cleanings until all the loose material is removed. Due to the high efficiency
of the cleaner, many older carpets will cause stuffing when the cleaner is
first used on them. If your vacuum cleaner does not pick up properly, or
makes unusual noise and the outer bag does not fluff up or balloon open,
follow these steps:
BAG INSTALLATION:
fig. 9 Slide the cardboard collar completely onto bag dock door.
fig. 10 Firmly push bag dock door with both thumbs on indication point
until it snaps.
How to Replace a Worn Belt
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 22 Check for blockage at the mouth of the intake opening. If there
is blockage, remove it with long-nose pliers, a screwdriver or
coat hanger. If you can not reach the blockage, remove
baseplate (fig. 23).
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 11 Remove the replacement belt from the storage channel.
fig. 12 Remove the door by removing the hold down screw located on
side of power head.
fig. 13 Slide the door forward by prying open with a screwdriver or
fig. 24 If the blockage is not at the base, remove lower tube. Unhook
coin.
retainer spring, releasing bottom of bag.
fig. 14 Remove the belt from the motor drive shaft and brush roll pulley.
fig. 25 Twist lower collar counterclockwise to slide up. Pull tube out of
base.
fig. 15 Loop the new belt over the motor drive shaft. Place the
opposite end of the belt on the brush roll pulley. Rotate the
brush roll three (3) complete revolutions to ensure that no part
of the belt is overhanging the end of the motor drive shaft.
fig. 26 Check for blockage. If blockage is in the tube, remove with a
coat hanger.
fig. 27 If tube is not blocked, look into fan housing. Remove debris
fig. 13 Replace the door by sliding it into the groove at the bottom of
with long-nose pliers, a screwdriver or coat hanger.
the housing.
fig. 12 Replace the hold down screw and tighten.
5
fig. 25 To reassemble, check O-ring on tube, and replace if damaged.
Vacuum will not operate properly without the tube O-ring. Slide
O-ring to approximately 2" from base of tube. Replace tube by
first lining up slot at base of tube with inner tab inside fan
housing. Then reinsert tube and push down until the tube is
seated. Make sure O-ring is in place against fan housing
opening. Replace and tighten collar until collar locking tabs are
locked in place.
fig. 28 Make sure collar is not cross threaded on housing. Reattach
bag spring (fig. 24).
fig. 29 Many times blockage occurs due to a full dust bag causing dirt to
back down the air flow system. When that happens, the
blockage will be at the top of the system, starting in the area
where the dust bag connects to the connector assembly.
NOTE: If the above actions do not correct the problem, contact an
Oreck Authorized Service Center or call the customer service center
at: 0845 603 0153.
6
©2006 Oreck Holdings, LLC. All rights reserved. All word marks, logos, product configurations, and registered trademarks are owned and used under the authority of Oreck
Holdings, LLC. Printed in America.
75724-03 REV B
12/06 ECN# R-8590
|
Miller Electric Welder and DS 75D16 User Manual
National Instruments Computer Drive NI USB 9229 User Manual
NEC Flat Panel Television V322AVT User Manual
Nortel Networks Router BSR252 User Manual
Omega Calculator DPF500 Series User Manual
Omron Network Card NT31 NT31C User Manual
Oregon Scientific Weather Radio BAR1000A User Manual
Palsonic Flat Panel Television 81CM Cordless Remote LCD Television Monitor User Manual
Panasonic Home Security System BL WV10 User Manual
Panasonic Security Camera BB HGW700A User Manual