Agilent 82357B
USB/GPIB
Interface
Quick Start Guide
Agilent Technologies
Safety Symbols
Caution, risk of danger (refer to this manual for specific Warning
or Caution information)
Regulatory Markings
The CE mark is a registered trademark of the European Commu-
nity. This CE mark shows that the product complies with all the
relevant European Legal Directives.
ICES/NMB-001 indicates that this ISM device complies with
the Canadian ICES-001. Cet appareil ISM est confomre a la
norme NMB-001 du Canada.
The CSA mark is a registered trademark of the Canadian Stan-
dards Association.
The C-tick mark is a registered trademark of the Spectrum Man-
agement Agency of Australia. This signifies compliance with
the Australia EMC Framework regulations under the terms of
the Radio Communication Act of 1992.
This instrument complies with the WEEE Directive
(2002/96/EC) marking requirement. This affixed product label
indicates that you must not discard this electrical or electronic
product in domestic household waste.
A CAUTION notice denotes a hazard. It calls attention to an
operating procedure, practice, or the like that, if not cor-
rectly performed or adhered to, could result in damage to
the product or loss of important data. Do not proceed
beyond a CAUTION notice until the indicated conditions
are fully understood and met.
CAUTION
A WARNING notice denotes a hazard. It calls attention to
an operating procedure, practice, or the like that, if not
correctly performed or adhered to, could result in
personal injury or death. Do not proceed beyond a
WARNING notice until the indicated conditions are fully
understood and met.
WARNING
III
Additional Safety Information
The following general safety precautions must be observed
during all phases of operation of this instrument.
•
•
Use the device with the cables provided.
CAUTION
Repair or service that is not covered in this manual
should only be performed by qualified personnels.
•
•
•
•
Do not use the device if it appears damaged or
defective.
WARNING
Observe all markings on the device before connecting
any wiring to the device.
Do no operate the device in the presence of flammable
gases or fumes.
Do no install substitute parts or perform any
unauthorized modification to the device.
Failure to comply with these precautions or with specific warn-
ings elsewhere in this manual violates safety standards of
design, manufacture, and intended use of the instrument. Agi-
lent Technologies, Inc. assumes no liability for the customer’s
failure to comply with these requirements.
This product is designed for use in compliance with:
•
•
•
IEC 61010-1:2001/EN 61010-1:2001
USA: UL61010-1:2004
Canada: CSA C22.2 No. 61010-1:2004
For further information on safety, refer to the 82357B User’s
Guide.
IV
82357B USB/GPIB Interface
Table of Contents
Introduction
1. Before You Install the 82357B
Check your shipment items
2
Check your PC operating system
2
2. Installing Agilent IO Libraries Suite
Insert the Automation-Ready CD
3
Install the IO Libraries Suite
3
Look for circled IO icon
4
3. Connecting the 82357B
Plug the 82357B into a USB Port
5
Observe the 82357B LEDs
5
4. Configuring the 82357B
Observe the Agilent Connection Expert
Configure the 82357B
6
6
5. Connecting GPIB Instruments
Connect the 82357B to GPIB instruments
7
6. Programming via the 82357B
Use the Agilent Interactive IO to communicate with the
GPIB instruments
8
Program the GPIB instruments (optional)
8
Other References
Related documentation
Contacting Agilent
9
9
82357B Quick Start Guide
V
82357B USB/GPIB Interface
Introduction
Introduction
This quick start guide shows a suggested six-step process to
install the 82357B and the Agilent IO Libraries Suite, to con-
nect the 82357B to your PC, to configure the 82357B, and to
program GPIB instruments via the 82357B. It also includes the
product technical specifications information.
The 82357B USB/GPIB Interface is supported ONLY for PCs
with Windows XP Professional, Windows Vista, or Windows 7
operating systems.
NOTE
The operating systems below are specifically not supported:
•
•
•
•
•
•
Windows 2000
Windows ME
Windows 98 (Second Edition)
Windows 98 First (“Gold”) Edition
Windows 95
Windows NT 4.0 (OS does not support USB)
In case of difficulty in installing the 82357B, see Chapter 3,
“Troubleshooting the Agilent 82357B” in the 82357B User’s
Guide.
82357B Quick Start Guide
1
82357B USB/GPIB Interface
1. Before You Install the 82357B
1. Before You Install the 82357B
Check your shipment items
Verify that you received the following items in your shipment of
the 82357B USB/GPIB Interface:
•
•
Agilent 82357B USB/GPIB Interface
Agilent Automation-Ready CD with Agilent IO Libraries
Suite
•
Printed copy of the Agilent 82357B USB/GPIB Interface
Quick Start Guide
If any item is missing or damaged, keep the shipping materials
and contact Agilent Technologies. See “Other References" on
page 9 later in this guide for our contact information.
Check your PC operating system
To install the 82357B USB/GPIB Interface, your PC operating
system must be one of the followings:
•
•
Windows® XP Professional (Service Pack 3 or later)
Windows Vista™ (32-bit and 64-bit) Service Pack 1 and 2 —
Home Basic, Home Premium, Business, and Ultimate
•
Windows 7 (32-bit and 64-bit) — Home Premium, Business,
and Ultimate
•
If you have the Agilent IO Libraries v14.2 installed and
would like to use 82357B USB/GPIB Interface, you will
need to install the 82357B driver. You can download the
driver from the Technical Support section on the following
site: http://www.agilent.com/find/82357B
NOTE
•
For the full list of the minimum system requirements, see
the 82357B User’s Guide.
2
82357B Quick Start Guide
82357B USB/GPIB Interface
2. Installing Agilent IO Libraries Suite
2. Installing Agilent IO Libraries Suite
Insert the Automation-Ready CD
Turn on your PC and insert the Agilent Automation- Ready CD
with Agilent IO Libraries Suite into the CD-ROM drive. If the
auto-run window does not appear automatically, go to Start >
Run then type <drive>:autorun\auto.exe, where
<drive> is your CD drive letter.
Install the IO Libraries Suite
•
•
See the 82357B User’s Guide for the full IO Libraries Suite
NOTE
installation procedures.
You are recommended to install the latest version of IO
Libraries Suite. You can download the latest version of IO
Libraries Suite from the following site:
When the Agilent IO Libraries Suite window appears, follow
the on-screen instructions to install the IO Libraries Suite.
82357B Quick Start Guide
3
82357B USB/GPIB Interface
2. Installing Agilent IO Libraries Suite
Upgrading your IO Libraries version
NOTE
If you are upgrading to the latest version of the IO Libraries
Suite from a previous version of the IO Libraries, you must
remove the following instruments and interfaces listed below
before you upgrade your software. This step is necessary in
order for these devices to obtain the correct drivers to work
with Agilent IO Libraries.
•
•
Disconnect any USB instruments from your PC.
Disconnect any Agilent 82357B USB/GPIB Interface con-
verters from your PC.
•
Disconnect any Agilent E8491 IEEE 1394 PC Link to VXI
interfaces from your PC.
Look for circled IO icon
After the libraries are installed, an IO icon is displayed on the
Windows task bar on the bottom-right corner of the screen.
You can click the icon to manually run the IO configuration util-
ities and to display the online documentation. It is not neces-
sary to use the icon at this time.
4
82357B Quick Start Guide
82357B USB/GPIB Interface
3. Connecting the 82357B
3. Connecting the 82357B
Plug the 82357B into a USB Port
Plug the 82357B USB cable into an available USB port on your
PC or on a supported USB hub. To connect to USB hubs, see
the 82357B User's Guide. The picture shown below is for illus-
tration purposes only. It is not necessary to connect the
82357B to any GPIB instruments at this time.
Observe the 82357B LEDs
Observe the three LEDs on the 82357B. Initially, only the red
FAIL LED should be illuminated. After 10 seconds, all three
LEDs should be illuminated to show that the 82357B has been
installed, and is configured for use with the IO Libraries.
READY LED
FAIL LED
82357B
USB Cable
ACCESS LED
If any LED is not illuminated after 10 seconds, see Chapter 3,
“Troubleshooting the Agilent 82357B” in the 82357B User's
Guide for more information.
NOTE
82357B Quick Start Guide
5
82357B USB/GPIB Interface
4. Configuring the 82357B
4. Configuring the 82357B
Observe the Agilent Connection Expert
Run the Agilent Connection Expert to verify your I/O configura-
tion: In the Windows Notification area, click the IO icon ( ),
then click Agilent Connection Expert.
When the main screen appears, you will see a map of the sys-
tem connections in the Instrument I/O on this PC pane (also
called the “Explorer Pane”). At this time, the Connection
Expert window should refresh. If it does not refresh automati-
cally, click Refresh All. The 82357B will appear in the Connec-
tion Expert explorer as a USB/GPIB interface as shown below.
Configure the 82357B
Once you see the 82357B displayed in the Connection Expert,
this means that it has been configured and can be used for pro-
gramming. At this time, only the green READY LED should
remain illuminated. To edit the configuration settings, click
Change Properties... in the detail pane on the right side of the
window.
See Chapter 2, “Using the Agilent 82357B” in the 82357B
User's Guide for more information on how to set the configura-
tion parameters.
NOTE
6
82357B Quick Start Guide
82357B USB/GPIB Interface
5. Connecting GPIB Instruments
5. Connecting GPIB Instruments
Connect the 82357B to GPIB instruments
Connect one or more GPIB instruments (up to 14 instruments
maximum) to the GPIB connector on the 82357B as shown
below:
•
Single instrument connection
82357B
GPIB Instrument
USB Cable
•
Multiple instruments connection
82357B
GPIB Instrument
USB Cable
GPIB Instrument
GPIB Cables
GPIB Instrument
To minimize stress on the connector mountings, stack no more
than three cable connector blocks.
NOTE
82357B Quick Start Guide
7
82357B USB/GPIB Interface
6. Programming via the 82357B
6. Programming via the 82357B
Use the Agilent Interactive IO to communicate with
the GPIB instruments
After the 82357B has been configured and connected to the
GPIB instruments, you can use the Interactive IO to establish
communication between your PC and the connected GPIB
instruments. To run the Interactive IO for an IEEE-488.2 compli-
ant instrument, perform the following:
1
Right click the instrument's icon in the Connection Expert
window.
2
3
Click Send Command to display the Interactive IO.
With the default command *IDN? displayed in the text
box, click Send & Read.
4
The instrument identification string should appear.
5
Repeat step 1 to step 3 for the next instrument.
Program the GPIB instruments (optional)
After communication has been established, you can program
your GPIB instruments using the VISA, VISA COM, or SICL
interfaces. See “Other References" on page 9 later in this
guide for the relevant documentation.
8
82357B Quick Start Guide
82357B USB/GPIB Interface
Other References
Other References
Related documentation
See the following documents for information related to the
82357B. All documents are available in electronic format by
clicking on the IO icon ( ) on the Windows task bar then
selecting Documentation.
•
•
•
Agilent 82357B USB/GPIB Interface User's Guide describes
the 82357B, and provides installation and troubleshooting
information.
Agilent IO Libraries Connectivity Guide provides a descrip-
tion of the Agilent IO Libraries and utilities, and detailed
installation information.
Agilent IO Libraries Suite Online Help provides detailed
usage information on the Agilent IO Libraries Suite utilities,
including the Connection Expert.
•
•
Agilent VISA User's Guide describes the Agilent Virtual
Instrument Software Architecture (VISA) library.
Agilent SICL User's Guide for Windows describes the Agi-
lent Standard Instrument Control Library (SICL) for Win-
dows.
Go to www.agilent.com/find/82357B for additional informa-
tion on the 82357B.
Contacting Agilent
You can reach Agilent Technologies at this telephone number
for the Americas:
Americas Call Center: 1- 800- 829- 4444
For other countries, contact your country’s Agilent support
organization.
A list of contact information for other countries is available on
the Agilent Web site: www.agilent.com/find/assist
82357B Quick Start Guide
9
82357B USB/GPIB Interface
Other References
10
82357B Quick Start Guide
Contact us
To obtain service, warranty or technical
assistance, contact us at the following phone
or fax numbers:
United States:
(tel) 800 829 4444
Canada:
(fax) 800 829 4433
(fax) 800 746 4866
(fax) 800 820 2816
(tel) 877 894 4414
China:
(tel) 800 810 0189
Europe:
(tel) 31 20 547 2111
Japan:
(tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Korea:
(tel) (080) 769 0800
Latin America:
(tel) (305) 269 7500
Taiwan:
(fax) (080) 769 0900
(tel) 0800 047 866
(fax) 0800 286 331
Other Asia Pacific Countries:
(tel) (65) 6375 8100
(fax) (65) 6755 0042
Or visit Agilent World Wide Web at:
Product specifications and descriptions in this
document are subject to change without
notice. Always refer to Agilent Web site for
the latest revision.
© Agilent Technologies, Inc., 2006 - 2009
Fifth Edition, August 1, 2009
82357-90700
Agilent Technologies
|
3Com Home Security System 3CRWE825075A User Manual
Adesso Mouse ACK 595 User Manual
Agilent Technologies Network Card 85032B E 50 User Manual
Aiphone Door CCS 1A User Manual
Aiphone Home Security System GH VAX User Manual
Alcatel Carrier Internetworking Solutions Telephone One Touch 531 User Manual
Alliance Laundry Systems Washer Dryer 25 Pound Capacity User Manual
Aluratek Digital Photo Frame ADMPF512F User Manual
AMX Stud Sensor IRX SM+ User Manual
Ayre Acoustics Stereo Amplifier K 5xe User Manual